๐Ÿ”ฅ Auxiliary Boiler Simulator

Stage 3 Aalborg OC Style | Soot Blowing | Scenarios
๐Ÿ“‹ BOILER DATA (Aalborg OC / SAACKE)
Type:Vertical Composite Design P:9.0 bar(g) Working P:7.0 bar(g) Steam Cap:0.75 - 5.0 t/h FW Temp:80ยฐC Control:se@vis BMS
โš  ALARM SETPOINTS
L1 Low Level:-80mm L2 Low Trip:-120mm High Level:+100mm FW Stop:+120mm Low Press:5.5 bar High Press Trip:9.0 bar
Fuel Mode
Fuel Type
FO Temp 130ยฐC
Burner Control
STANDBY
Steam Pressure Control
Setpoint 7.0 bar
Mode
Drum Level Control
Setpoint (NWL) 0 mm
Control Mode
Combustion / Oโ‚‚ Trim
Oโ‚‚ Setpoint 3.5%
Oโ‚‚ Trim
Steam Demand (Load)
Demand 50%
๐Ÿ’ง Blowdown Control
Bottom Blowdown CLOSED
0 / 10s
Surface Blowdown 0%
Continuous BD
Valve Position 0%
TDS Setpoint 2500 ppm
๐Ÿ’จ Soot Blower Control
Tube Fouling 0%
Heat Transfer Eff. 100%
Blower Status READY
0 / 30s
READY
โ†’
INSERT
โ†’
BLOW
โ†’
RETRACT
Interlocks
Burner Firing
Steam Pressure > 5 bar
No Sequence Active
Simulation Speed
Process Values
Pressure 0.0 bar
Level 0 mm
Flue Oโ‚‚ 21.0 %
Firing 0 %
FW Valve 0 %
FW Flow 0.0 t/h
Steam Flow 0.0 t/h
FO Temp 130 ยฐC
TDS 1500 ppm
Soot 0 %
๐ŸŒŠ Plant Dynamics
OFF: Stable demand
GENTLE: Slow drift ยฑ10%
ACTIVE: Swings ยฑ25%, steps
๐Ÿ“‹ Training Scenarios
Alarm Panel
LOW LEVEL 1st
LOW LEVEL TRIP
HIGH LEVEL
HI LEVEL FW STOP
LOW PRESSURE
HIGH PRESS TRIP
FLAME FAILURE
FAN FAILURE
FO LOW PRESS
FO HIGH TEMP
FO LOW TEMP
HIGH OPACITY
STEAM HAMMER
BD TIMEOUT
BD VALVE STUCK
HIGH TDS
HIGH SOOT
SOOT FIRE
BLOWER FAULT
Inject Disturbance
Sensor Failures